New Products

New Products

ITE/Industrial Class II Adapter
Model Power Input Voltage Output Voltage Features
NEW TRE36 36W 90-264 5V, 9V, 12V, 13.5V, 15V, 18V, 24V, 36V, 48V
Medical Class I & Class II Adapter
Model Power Input Voltage Output Voltage Features
NEW TR70M 70W 80-264V 12V, 15V, 18V, 24V, 36V, 48V 2 MOPP, CoC Tier 2 & DoE Level VI, Class I & Class II, Altitude 5000m, Meets IEC/EN60335-1
Medical Class II Adapter
Model Power Input Voltage Output Voltage Features
NEW TR36M 36W 80-264 5V, 9V, 12V, 13.5V, 15V, 18V, 24V, 36V, 48V 2 MOPP, Level VI, Class II, Altitude 5000m, Low Leakage Current <80uA, Approved EN60601-1-11 IP21, Meets IEC/EN60335-1
ITE/Industrial On-Board Open Frame
Model Power Input Voltage Output Voltage Features
NEW CFM41S 40W 90-264 12V, 15V, 24V, 36V, 48V, 5V 2.000x2.000x1.01 Inches
Operating Temperature -40℃~85℃, Altitude 5000m
Approved IEC/UL/EN 62368-1
Meets IEC/EN60335-1(61558-1)
Class Ⅱ, Peak Load (twice the rated power)
NEW CFM06S 6W 90-264 3.3V, 5V, 9V, 12V, 15V, 24V 1.555x0.764x0.720 Inches
Operating Temperature -40℃~80℃, Altitude 5000m
Approved IEC/UL/EN 62368-1
Meets IEC/EN60335-1(61558-1)
Class Ⅱ, IoT Applications
    CFM12S 12W 90-264 5V, 9V, 12V, 15V, 24V 1.500x1.000x0.764 Inches
Operating Temperature -40℃~75℃, Altitude 5000m
Approved IEC/UL/EN 62368-1
Meets IEC/EN60335-1(61558-1)
Class Ⅱ, IoT Applications
    CFM25S 25W 90-264 5V, 12V, 15V, 24V, 36V, 48V 2.000x1.100x0.980 Inches
Operating Temperature -30℃~70℃, Altitude 5000m
Approved IEC/UL/EN 62368-1
Meets IEC/EN60335-1(61558-1)
Class Ⅱ, Peak Load (twice the rated power)
NEW CFM61S 60W 90-264 5V, 12V, 15V, 24V, 36V, 48V 2.000x2.000x1.346 Inches
Operating Temperature -30℃~70℃, Altitude 5000m
Approved IEC/UL/EN 62368-1
Class Ⅱ, Peak Load (twice the rated power)
ITE/Industrial Baseplate-cooled Open Frame
Model Power Input Voltage Output Voltage Features
NEW CFM150S 120W, 150W 90-264 12V, 24V, 28V, 36V, 48V 4.000x2.000x1.283 Inches
Operating Temperature -30℃~80℃, Altitude 5000m
Approved IEC/UL/EN 62368-1
Meets IEC/EN60335-1(61558-1)
ClassⅠ&Ⅱ, No Load <0.15W
    CFM300S 300W 90-264 12V, 24V, 36V, 48V High Efficiency
Medical Interchangeable Plug Adapter
Model Power Input Voltage Output Voltage Features
NEW TR30RDM 30W 80-264 5V, 9V, 12V, 15V, 18V, 24V 2 MOPP, Level VI, Class II, Altitude 5000m, Low Leakage Current <50uA, Approved EN60601-1-11 IP22, Meets IEC/EN60335-1
Medical On-Board Open Frame
Model Power Input Voltage Output Voltage Features
    CFM21M 20W 90-264 5V, 9V, 12V, 15V, 24V 2.38"x 1.6” Size, Low Profile 0.8”, 2 MOPP, Class Ⅱ,
Meets IEC/EN60335-1, Different types of packaging
Medical Baseplate-cooled Open Frame
Model Power Input Voltage Output Voltage Features
NEW CFM130M 130W 80-264V 12V, 24V, 36V, 48V 3.000x2.000x1.20 Inches
Operating Temperature -30℃~70℃, Altitude 5000m
Approved IEC/UL/EN 60601-1, 2 MOPP
Meets IEC/EN60335-1(61558-1)
ClassⅠ&Ⅱ, No Load <0.15W
    CFM200M 200W 90-264 12V, 24V, 48V 2"x 4”Compact Size, 2 MOPP, ClassⅠ&Ⅱ,
Meets IEC/EN60335-1
    CFM300M 300W 90-264 12V, 24V, 36V, 48V 3"x 5”Compact Size, 2 MOPP, ClassⅠ,
Meets IEC/EN60335-1
CLOSE

We use cookies to provide the services and features offered on our website, and to improve our user experience. By using this website, you consent to the use of cookies.